Product Shortcut

 
 
 
 
 
 
AUTODEST® 851 AC
Fully Computer Controlled-Boiling Analysis
according to ASTM D-1160

The FISCHER technology® AUTODEST® 851 AC is a fully computer controlled unit of turn-key design, and ready for use after installation and commissioning. The unit extends the current test method and does not limit your vacuum distillation testing options.

You are able to define your own tailored program also beyond the current standard.The system is fully housed and equipped with doors in the front and rear to satisfy safety requirements and to facilitate service aspects.

The protocol is printed out simultaneously to the distillation and the distillation curves in actual boiling temperatures (ACT) and atmospheric equivalent temperatures (AET) as well as essential distillation parameters are shown on the monitor.

The final data and the distillation curves are printed and stored on harddisk and/or data disks.
 

 
AUTODEST® 800 AC
Fully Computer Controlled Distillation System
according to ASTM D-2892 (TBP)
 
The FISCHER technology® AUTODEST® 800 AC is a fully computer controlled unit of turn-key design, and ready for use after installation and commissioning. The system is fully housed and equipped with doors in the front and rear to satisfy safety requirements and to facilitate service aspects.
 
The automatic fraction collector with 20 receivers includes a built-in internal balance for the determination of the fraction weight, while the separate volume follower system is used for discharging the fractions into the final receivers and the determination of the fraction volume as well as for the direct distillation rate control.
 
The vacuum equipment and the control system are designed for highest accuracy, repeatability and reproducibility of data.
 


AUTODEST® 860 AC
Fully Computer Controlled Distillation System
according to ASTM D-5236 (Potstill)
 
  
The FISCHER technology® AUTODEST® 860 AC is a fully computer controlled unit of turn-key design, and ready for use after installation and commissioning. The system is fully housed and equipped with doors in the front and rear to satisfy safety requirements and to facilitate service aspects.
  
The automatic fraction collector with 12 receivers includes a built-in internal balance, which is used for the simultaneous determination of the fraction weight and for the direct distillation rate control.
  
The vacuum equipment and the control system are designed for highest accuracy, repeatability and reproducibility of data.
  

 
AUTODEST® 860 HV
Fully Computer Controlled Distillation System according
to ASTM D-5236 (Potstill) with EXTENSION “HV” for
High Vacuum Operation up to 620°…650°C AET
 
  
The FISCHER technology® AUTODEST® 860 AC can be converted to the “HV”-version by adding an extended Potstill-column to the standard ASTM-system (Potstill). The respective distillation process is performed in the range of 0.005…0.1 mm Hg.
 
The FISCHER technology® AUTODEST® 860 HV 6 ltr is a fully computer controlled unit of turn-key design, and ready for use after installation and commissioning. The system is fully housed and equipped with doors in the front and rear to satisfy safety requirements and to facilitate service aspects.
 
The automatic fraction collector with 12 receivers includes a built-in internal balance, which is used for the simultaneous determination of the fraction weight and for the direct distillation rate control.
 
The vacuum equipment and the control system are designed for highest accuracy, repeatability and reproducibility of data.
 
The i-Fischer® DIST D-5236 HV is also available with a capacity of 50 ltrs.
 
 

FISCHER® LABODEST® HMS 500 AC
 
Automatic Semi-Micro-Distillation-Unit with the
FISCHER® SPALTROHR®-Column
  
Compact and especially versatile, the fully automated FISCHER technology® LABODEST® HMS 500 AC is a unit with highest separation efficiency. A modular system, which can be designed according to specific requirements including an equipment for recording the distillation curve or for printing-out the distillation record by means of a printer or for connection for electronic data processing.

Technical Data:
 
Charge Quantity:            10...500 ml
Operation Temperature:   up to 250°C respectively
                                     up to 350°C (option B necessary)
Operation Pressure:        Atmospheric or
                                     Vacuum 100... 0.1 mbar (option A necessary)
Pressure Drop:               < 0.1 mbar
Separation Efficiency:     up to 90 theoretical plates
Mains Supply:                230 V, 50 Hz
Dimensions (w x d x h):  1.25 x 0.60 x 1.70 m
Weight:                         approx. 100 kg
 
 

FISCHER® VLE
  
The FISCHER technology® VLE can be applied for measuring equilibrium data and evaluation of equilibrium curves. These curves are used for the calculation of necessary separation efficiencies of distillation columns.
  • 1 universal glass apparatus, complete with silvered vacuum mantle, cooler, circulation evaporator and vacuum-tight screwing for sample take-off by means of a syringe, with works certificate “Operation Pressure”
  • 1 immersion heater 350 W, with special surface finish to avoid bumping
  • 1 magnetic stirrer for intensive mixing
  • 10 final receivers with screw caps
  • 1 filling funnel with PTFE stopcock
  • 2 solenoid coils
  • 1 liquid temperature sensor Pt-100, with connection cable and plug
  • 1 vapour temperature sensor Pt-100, complete with connection cable and plug, optionally calibrated
  • 1 Phase Equilibrium Controller FISCHER MINITRON [VLE]2 with modern micro-electronics, offers high operating comfort, safety and reliability, with menu guided operation by push-turn-knob
  • Electronic control box with micro processor controller. Connectable to a PC for data input, data display and storage by means of an interface 
 

FISCHER® OZ Ozone Generator
Portable ozone generator for universal laboratory and
industrial uses, suited for oxygen and dried air as feed gas
  
All technical data are based on use of oxygen with operation pressure at relative 0...0.2 bar. Upon request the generators can also be used in process systems with a pressure over 0.2 bar rel. (max. 1.5 bar rel.). The gas flow is adjustable at the precision neddle valve of the sophisticated flow meter.
 
For reproducing the ozone production, on a 3 1/2-digit LCD display the actual ozone concentration is shown. The electrical controller allows continuous adjustment of the ozone concentration between 5 and 100%.
 
The ozone-generating module is made of inert material and is built together with the power supply and the instrumentation into a steel housing with an aluminium front and rear side, air ventilation cooler and carry on handle.
 
 
[DC/MoS]2 Control System
 
PC-based Control System for Automated Operation
  
The use of a computer-aided system is well suited for the control and regulation of distillation and rectification plants: the wide range of measurement and regulating tasks, the need for flexibility, ease of operation and a display of the operating parameters make the use of a computer with the relevant software and peripherals appear the ideal solution. Particular attention was paid to the following points when developing the regulating system for distillation plants:
  • optimum separating performance by the individual plant thanks to easy adaptability, including changing distillation tasks
  • simple operation through menu control
  • withdrawal of further cuts into separate receivers
  • intermittend operation for getting an optimum in distillate quality and quantity
Process sequences, regulating concepts and algorythms can be altered via the program without the need to intervene via the hardware. The system for controlling distillation and rectification plants comprises the following components:
  • sensors within the plant: resistance thermometers, pressure probes, level probes etc.
  • actuators in the plant: solenoid valves, heating elements, liquid and vacuum pumps, motorized regulating units etc.
  • personal computer and accessories
  • ILUDEST® [DC/MoS]2 unit as an interface between distillation plant and PC
 

Solvent Recycling – Type LM
 
 
The introduction of an automized distillation unit, designed by ILUDEST®, is one of the more effective means of improving efficiency. In fact, separations are sometimes so complete that it is often possible to recover solvents whose purity exceeds that of the original, newly-purchased material.
 
Objections to solvent recycling are usually based on concerns about the adequacy of the recovered product and the expected effort required to complete the distillation. The first concern has been addressed above and we see that, for most clinical applications, very pure materials can be recovered. The work involved in completing a distillation was considerable until the introduction in recent years of automated equipment.
 
An example of a state-of-the-art distillation apparatus is the ILUDEST® Model LM-6/H Computerised Recycling System.
 
The instrument has a capacity of 6 litres of solvent mixture with a throughput of up to 1 l/hr (when recovering xylene). A microcomputer controller holds up to 100 programs as well as monitoring the distillation process for normal and safe operation. Variable reflux ratios and equilibrium times are possible so that the operator has maximum flexibility to design a program for optimal efficiency.
 
Other capacities are available upon request. Please enquire!
 

 
Teaching Units for Thermal Process Engineering – Type AUSB
 
  
ILUDEST® designs/manufactures a comprehensive range of Teaching Units for the Thermal Process Engineering, e.g. Continuous/Batch Distillation, Thin Film Evaporation, Short Path Evaporation, Pulsed Counter Current Extraction, Absorption/Desorption, Residence Time Determination (Reactor/Cascade) etc.
 
Other types and/or customised versions are available upon request. Please enquire!
 
 
 
for more information : http://www.fischer-technology.de
 

 

Copyright © 2011   Ilab Fluid Control Co., Ltd. All right reserved.