MD 100 Photometer

SKU : MD100
Precise water control with proven and compact measuring system

Products
Description
Parameter
TitleParameter and RangePart number
SingleMD 100 Aluminium, tablet reagents
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with aluminium reagent tablets.
Aluminium PP 0.01 - 0.25 mg/L Al
Aluminium T 0.01 - 0.3 mg/L Al
276200
SingleMD 100 Aluminium, powder reagents
The mobile photometer works with LEDs, interference filters and automatic storage. The measurement is performed with aluminium powder reagent.
Aluminium PP 0.01 - 0.25 mg/L Al
Aluminium T 0.01 - 0.3 mg/L Al
276205
SingleMD 100 Ammonia, tablet reagents
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with ammonium reagent tablets.
Ammonia PP 0.01 - 0.8 mg/L N
Ammonia T 0.02 - 1 mg/L N
276060
SingleMD 100 Ammonia, powder reagents
The mobile photometer works with LEDs, interference filters and automatic storage. The measurement is performed with ammonium powder reagent.
Ammonia PP 0.01 - 0.8 mg/L N
Ammonia T 0.02 - 1 mg/L N
276065
SingleMD 100 Chlorine, tablet reagents
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with chlorine reagent tablets.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
276000
SingleMD 100 Chlorine, liquid reagents
The mobile photometer works with LEDs, interference filters and automatic storage. The measurement is carried out with chlorine liquid reagent.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
276005
SingleMD 100 Chlorine DUO, tablet reagents
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with reagent tablets for different types of chlorine.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine PP 0.02 - 2 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
276020
SingleMD 100 Chlorine DUO, powder reagents
The mobile photometer works with LEDs, interference filters and automatic storage. Powder reagents determine different types of chlorine.
Chlorine HR PP 0.1 - 8 mg/L Cl2 a)
Chlorine PP 0.02 - 2 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
276025
SingleMD 100 Chlorine, powder reagents
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with powder reagent.
Chlorine HR PP 0.1 - 8 mg/L Cl2 a)
Chlorine PP 0.02 - 2 mg/L Cl2 a)
276010 
SingleMD 100 Chlorine HR (potassium iodide), tablet reagents
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tablet reagents for HR chlorine.
Chlorine HR (KI) T 5 - 200 mg/L Cl2276170
SingleMD 100 Chlorine dioxide, tablet reagents
The mobile photometer works with LEDs, interference filter and automatic storage. The measurement is carried out with chlorine dioxide reagent tablets.
Chlorine dioxide PP 0.04 - 3.8 mg/L ClO2
Chlorine dioxide T 0.02 - 11 mg/L ClO2
276030 
SingleMD 100 Chlorine dioxide, powder reagents
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with powder reagents for chlorine dioxide.
Chlorine dioxide PP 0.04 - 3.8 mg/L ClO2
Chlorine dioxide T 0.02 - 11 mg/L ClO2
276035 
SingleMD 100 Chloride, tablet reagents
The mobile photometer works with LEDs, interference filter and automatic storage. The measurement is performed with chloride reagent tablets.
Chloride T 0.5 - 25 mg/L Cl-
Chloride T 5 - 250 mg/L Cl- i)
276180
SingleMD 100 COD, tube tests
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tube tests for COD.
COD HR TT 200 - 15000 mg/L CODb)
COD LMR TT 15 - 300 mg/L CODb)
COD LR TT 3 - 150 mg/L CODb)
COD MR TT 20 - 1500 mg/L CODb)
276120
SingleMD 100 Iron, tablet reagents
The mobile photometer works with LEDs, interference filter and automatic storage. The measurement is performed with iron reagent tablets.
Iron (TPTZ) PP 0.02 - 1.8 mg/L Fe
Iron PP 0.02 - 3 mg/L Feg)
Iron T 0.02 - 1 mg/L Fe
276050
SingleMD 100 Iron TPTZ, powder reagents
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with powder reagents for iron TPTZ.
Iron (TPTZ) PP 0.02 - 1.8 mg/L Fe
Iron PP 0.02 - 3 mg/L Feg)
Iron T 0.02 - 1 mg/L Fe
276055 
SingleMD 100 Iron, powder reagents
The mobile photometer works with LEDs, interference filter and automatic storage. The measurement is performed with iron powder reagent.
Iron (TPTZ) PP 0.02 - 1.8 mg/L Fe
Iron PP 0.02 - 3 mg/L Feg)
Iron T 0.02 - 1 mg/L Fe
276056
SingleMD 100 Fluoride (without reagents)
The mobile photometer works with LEDs, interference filters and automatic memory.
Fluoride L 0.05 - 2 mg/L F-276090
SingleMD 100 Hardness, total, tablet reagents
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with reagent tablets for total hardness.
Hardness total HR T 20 - 500 mg/L CaCO3 i)
Hardness total T 2 - 50 mg/L CaCO3
276190 
SingleMD 100 Urea, tablet reagents
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tablet reagents for urea.
Urea T 0.1 - 2.5 mg/L Urea
Urea T 0.2 - 5 mg/L Ureai)
276210
SingleMD 100 Hazen/A.P.H.A., no reagents required
The mobile photometer works with LEDs, interference filters and automatic storage. No reagent is required for the Hazen/A.P.H.A. check.
Hazen 24 10 - 500 mg/L Pt276160
SingleMD 100 Copper, tablet reagents
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with tablet reagents for copper.
Copper PP 0.05 - 5 mg/L Cu
Copper T 0.05 - 5 mg/L Cua)
276080
SingleMD 100 Copper, powder reagents
The mobile photometer works with LEDs, interference filter and automatic storage. The measurement is performed with copper powder reagent.
Copper PP 0.05 - 5 mg/L Cu
Copper T 0.05 - 5 mg/L Cua)
276085
SingleMD 100 Manganese LR, tablet reagents
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tablet reagents for manganese LR.
Manganese HR PP 0.1 - 18 mg/L Mn
Manganese LR PP 0.01 - 0.7 mg/L Mn
Manganese T 0.2 - 4 mg/L Mn
276100
SingleMD 100 Manganese LR, powder reagents
The mobile photometer works with LEDs, interference filter and automatic storage. The measurement is performed with manganese LR powder reagent.
Manganese HR PP 0.1 - 18 mg/L Mn
Manganese LR PP 0.01 - 0.7 mg/L Mn
Manganese T 0.2 - 4 mg/L Mn
276105
SingleMD 100 Manganese HR, powder reagents
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with reagent powder for manganese HR.
Manganese HR PP 0.1 - 18 mg/L Mn
Manganese LR PP 0.01 - 0.7 mg/L Mn
Manganese T 0.2 - 4 mg/L Mn
276106
SingleMD 100 Molybdenum LR, powder reagents/ tablet reagents
The mobile photometer works with LEDs, interference filter, automatic storage. The molybdenum measurement is performed with reagent tablets and powders.
Molybdate HR PP 0.3 - 40 mg/L Mo
Molybdate LR PP 0.03 - 3 mg/L Mo
Molybdate T 0.6 - 50 mg/L MoO4
276140
SingleMD 100 Molybdenum HR, powder reagents
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with reagent powder for molybdenum HR.
Molybdate HR PP 0.3 - 40 mg/L Mo
Molybdate LR PP 0.03 - 3 mg/L Mo
Molybdate T 0.6 - 50 mg/L MoO4
276141
SingleMD 100 Molybdenum, tablet reagents
The mobile photometer works with LEDs, interference filter, automatic storage. The molybdenum measurement is performed with tablet reagents.
Molybdate HR PP 0.3 - 40 mg/L Mo
Molybdate LR PP 0.03 - 3 mg/L Mo
Molybdate T 0.6 - 50 mg/L MoO4
276142
SingleMD 100 Phosphate, tablet reagents
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tablet reagents for phosphate
Phosphate LR T 0.02 - 1.3 mg/L P
Phosphate PP 0.02 - 0.8 mg/L P
276040
SingleMD 100 Phosphate, powder reagents
The mobile photometer works with LEDs, interference filter, automatic storage. The phosphate measurement is performed with powder reagent.
Phosphate LR T 0.02 - 1.3 mg/L P
Phosphate PP 0.02 - 0.8 mg/L P
276045
SingleMD 100 Silica, tablet reagents
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tablet reagents for silicate.
Silicate HR PP 1 - 90 mg/L SiO2
Silicate LR PP 0.1 - 1.6 mg/L SiO2
Silicate T 0.05 - 4 mg/L SiO2
276110
SingleMD 100 Silica LR, powder reagents
The mobile photometer works with LEDs, interference filter, automatic storage. The silicate LR measurement is performed with powder reagent.
Silicate HR PP 1 - 90 mg/L SiO2
Silicate LR PP 0.1 - 1.6 mg/L SiO2
Silicate T 0.05 - 4 mg/L SiO2
276115
SingleMD 100 Silica HR, powder reagents
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with powder reagent for silicate HR.
Silicate HR PP 1 - 90 mg/L SiO2
Silicate LR PP 0.1 - 1.6 mg/L SiO2
Silicate T 0.05 - 4 mg/L SiO2
276116
SingleMD 100 Suspended solids, no reagents required
The mobile photometer works with LEDs, interference filters, automatic storage. No reagent is necessary for the measurement.
Suspended solids 24 10 - 750 mg/L TSS276150
2in1MD 100 Chlorine, pH, tablet reagents (OTZ)
LEDs, interference filters, automatic storage: The mobile and ergonomic photometer works with reagent tablets for chlorine and pH.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278020
2in1MD 100 Chlorine, pH, liquid reagents (OTZ)
The mobile photometer works with LEDs, interference filter, automatic storage. The chlorine/pH measurement is carried out with liquid reagents.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278025
2in1MD 100 Chlorine, pH, powder reagents for chlorine
The mobile photometer works with LEDs, interference filter, automatic storage. The chlorine measurement is carried out with powder reagents.
Chlorine HR PP 0.1 - 8 mg/L Cl2 a)
Chlorine PP 0.02 - 2 mg/L Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278030
3in1MD 100 Chlorine, pH, Cyanuric acid, tablet reagents (OTZ)
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with reagent tablets for chlorine, pH and cyanuric acid.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
CyA T 10 - 160 mg/L CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278010
3in1MD 100 Chlorine, pH, Cyanuric acid, liquid reagents for Chlorine and pH (OTZ)
The mobile photometer works with LEDs, interference filter, automatic storage. The chlorine/pH measurement is performed with liquid reagents.
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cla)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
CyA T 10 - 160 mg/L CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278015
3in1MD 100 Chlorine, pH, Alkalinity-m, tablet reagents (OTZ)
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with reagent tablets for chlorine, pH and alkalinity-m.
Alkalinity-m T 5 - 200 mg/L CaCO3
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278060
3in1MD 100 Chlorine, pH, Alkalinity-m, liquid reagents for Chlorine and pH (OTZ)
The mobile photometer works with LEDs, interference filter, automatic storage. The measurement is performed with liquid reagents.
Alkalinity-m T 5 - 200 mg/L CaCO3
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278065
2in1MD 100 Chlorine LR, Chlorine HR, Chlorine dioxide, tablet reagents
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer works with tablet reagents for chlorine LR, chlorine HR and chlorine dioxide.
Chlorine dioxide T 0.02 - 11 mg/L ClO2
Chlorine HR (KI) T 5 - 200 mg/L Cl2
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
278000
4in1MD 100 Chlorine, pH, Cyanuric acid, Alkalinity-m, tablet reagents (OTZ)
The mobile photometer works with LEDs, interference filter, automatic storage. Chlorine, pH, cyanuric acid, alkalinity-m.
Alkalinity-m T 5 - 200 mg/L CaCO3
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
CyA T 10 - 160 mg/L CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278070
4in1MD 100 Chlorine, pH, Cyanuric acid, Alkalinity-m, liquid reagents for Chlorine and pH (OTZ)
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures chlorine and pH (liquid), cyanuric acid, alkalinity-m.
Alkalinity-m T 5 - 200 mg/L CaCO3
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
CyA T 10 - 160 mg/L CyA
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278075
4in1MD 100 Chlorine DUO, Chlorine HR, pH, Alkalinity-m, Calcium hardness (OTZ)
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures chlorine DUO, chlorine, pH, alkalinity-m, calcium hardness.
Alkalinity-m T 5 - 200 mg/L CaCO3
Chlorine HR (KI) T 5 - 200 mg/L Cl2
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine MR PP 0.02 - 3.5 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
Hardness Calcium (B) T 20 - 500 mg/L CaCO3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278160
5in1MD 100 Chlorine, pH, Cyanuric acid, Alkalinity-m, Calcium hardness, tablet reagents (OTZ)
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures chlorine, pH, cyanuric acid, alkalinity-m, calcium hardness.
Alkalinity-m T 5 - 200 mg/L CaCO3
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
CyA T 10 - 160 mg/L CyA
Hardness Calcium (B) T 20 - 500 mg/L CaCO3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278080
6in1MD 100 Chlorine, Bromine, pH, Cyanuric acid, Alkalinity-m, Calcium hardness, tablet reagents (OTZ)
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures chlorine, bromine, pH, cyanuric acid, alkalinity-m, calcium hardness.
Alkalinity-m T 5 - 200 mg/L CaCO3
Bromine T 0.05 - 13 mg/L Br2
Chlorine HR T 0.1 - 10 mg/L Cl2 a)
Chlorine L 0.02 - 4.0 mg/L Cl2 a)
Chlorine T 0.01 - 6.0 mg/L Cl2 a)
CyA T 10 - 160 mg/L CyA
Hardness Calcium (B) T 20 - 500 mg/L CaCO3
pH value L 6.5 - 8.4
pH-value T 6.5 - 8.4
278090
Boiler WaterMD 100 Boiler Water
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures 10 parameters from aluminium to silicate.
Aluminium PP 0.01 - 0.25 mg/L Al
Chloride L (B) 0.5 - 20 mg/L Cl-
Copper T 0.05 - 5 mg/L Cua)
DEHA PP 0.02 - 0.5 mg/L DEHA
Hydrazine P 0.05 - 0.5 mg/L N2H4
Iron LR L (A) 0.03 - 2 mg/L Fe
Oxygen dissolved C 10 - 800 µg/L O2 c)
Phosphate HR L 5 - 80 mg/L PO4
Polyacrylate L 1 - 30 mg/L Polyacryl
Silicate HR PP 1 - 90 mg/L SiO2
276230
Cooling WaterMD 100 Cooling Water
LEDs, interference filter, automatic storage: The mobile and ergonomic photometer measures 10 parameters from aluminium to zinc.
16 Parameters276240