Parameter | Title | Parameter and range | Part number |
2in1 | MD150 Chlorine, pH, tablet reagents The MD150 mobile photometer works with LED, spectrometric sensor, automatic storage. The photometer offers various parameter configurations and is compatible with tablets, liquid and powder reagents. | Chlorine HR 2 PP 0.1 - 10 mg/L Cl2 Chlorine HR T 0.1 - 10 mg/L Cl2 a) Chlorine L 0.02 - 4.0 mg/L Cl2 a) Chlorine PP 0.02 - 2 mg/L Cl2 a) Chlorine T 0.02 - 6.0 mg/L Cl2 a) pH value L 6.5 - 8.4 pH-value T 6.5 - 8.4 | 282100 |
2in1 | MD150 Chlorine, pH liquid reagents The MD150 mobile photometer works with LED, spectrometric sensor, automatic storage. The photometer offers various parameter configurations and is compatible with tablets, liquid and powder reagents. | Chlorine HR 2 PP 0.1 - 10 mg/L Cl2 Chlorine HR T 0.1 - 10 mg/L Cl2 a) Chlorine L 0.02 - 4.0 mg/L Cl2 a) Chlorine PP 0.02 - 2 mg/L Cl2 a) Chlorine T 0.02 - 6.0 mg/L Cl2 a) pH value L 6.5 - 8.4 pH-value T 6.5 - 8.4 | 282102 |
2in1 | MD150 Chlorine, pH, powder reagents The MD150 mobile photometer works with LED, spectrometric sensor, automatic storage. The photometer offers various parameter configurations and is compatible with tablets, liquid and powder reagents. | Chlorine HR 2 PP 0.1 - 10 mg/L Cl2 Chlorine HR T 0.1 - 10 mg/L Cl2 a) Chlorine L 0.02 - 4.0 mg/L Cl2 a) Chlorine PP 0.02 - 2 mg/L Cl2 a) Chlorine T 0.02 - 6.0 mg/L Cl2 a) pH value L 6.5 - 8.4 pH-value T 6.5 - 8.4 | 282105 |
3in1 | MD150 Chlorine, pH, Cyanuric acid, tablet reagents The MD150 mobile photometer works with LED, spectrometric sensor, automatic storage. The photometer offers various parameter configurations and is compatible with tablets, liquid and powder reagents. | Chlorine HR 2 PP 0.1 - 10 mg/L Cl2 Chlorine HR T 0.1 - 10 mg/L Cl2 a) Chlorine L 0.02 - 4.0 mg/L Cl2 a) Chlorine PP 0.02 - 2 mg/L Cl2 a) Chlorine T 0.02 - 6.0 mg/L Cl2 a) CyA HR T 10 - 200 mg/L CyA pH value L 6.5 - 8.4 pH-value T 6.5 - 8.4 | 282110 |
3in1 | MD150 Chlorine, pH, Cyanuric acid, liquid reagents The MD150 mobile photometer works with LED, spectrometric sensor, automatic storage. The photometer offers various parameter configurations and is compatible with tablets, liquid and powder reagents. | Chlorine HR 2 PP 0.1 - 10 mg/L Cl2 Chlorine HR T 0.1 - 10 mg/L Cl2 a) Chlorine L 0.02 - 4.0 mg/L Cl2 a) Chlorine PP 0.02 - 2 mg/L Cl2 a) Chlorine T 0.02 - 6.0 mg/L Cl2 a) CyA HR T 10 - 200 mg/L CyA pH value L 6.5 - 8.4 pH-value T 6.5 - 8.4 | 282112 |
3in1 | MD150 Chlorine, Chlorine HR (potassium iodide), Chlorine dioxide The MD150 mobile photometer works with LED, spectrometric sensor, automatic storage. The photometer offers various parameter configurations and is compatible with tablets, liquid and powder reagents. | Chlorine dioxide PP 0.04 - 3.8 mg/L ClO2 Chlorine dioxide T 0.04 - 11 mg/L ClO2 Chlorine HR 2 PP 0.1 - 10 mg/L Cl2 Chlorine HR (KI) T 5 - 200 mg/L Cl2 Chlorine HR T 0.1 - 10 mg/L Cl2 a) Chlorine L 0.02 - 4.0 mg/L Cl2 a) Chlorine PP 0.02 - 2 mg/L Cl2 a) Chlorine T 0.02 - 6.0 mg/L Cl2 a) | 282120 |
4in1 | MD150 Chlorine, Chlorine dioxide, pH, KS4.3 The MD150 mobile photometer works with LED, spectrometric sensor, automatic storage. The photometer offers various parameter configurations and is compatible with tablets, liquid and powder reagents. | Multiparameter | 282130 |
5in1 | MD150 Chlorine, Bromine, pH, Chlorine dioxide, Ozone The MD150 mobile photometer works with LED, spectrometric sensor, automatic storage. The photometer offers various parameter configurations and is compatible with tablets, liquid and powder reagents. | Multiparameter | 282140 |
6in1 | MD150 Chlorine, Bromine, pH, Cyanuric Acid, Alkalinity-m, Calcium Hardness The MD150 mobile photometer works with LED, spectrometric sensor, automatic storage. The photometer offers various parameter configurations and is compatible with tablets, liquid and powder reagents. | Multiparameter | 282150 |